Search Results (93 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-5550 1 Tenda 1 Ac10 Firmware 2026-04-05 8.8 High
A vulnerability was identified in Tenda AC10 16.03.10.10_multi_TDE01. This affects the function fromSysToolChangePwd of the file /bin/httpd. The manipulation leads to stack-based buffer overflow. The attack may be initiated remotely. Multiple endpoints might be affected.
CVE-2026-5549 1 Tenda 1 Ac10 Firmware 2026-04-05 5.3 Medium
A vulnerability was determined in Tenda AC10 16.03.10.10_multi_TDE01. Affected by this issue is some unknown functionality of the file /webroot_ro/pem/privkeySrv.pem of the component RSA 2048-bit Private Key Handler. Executing a manipulation can lead to use of hard-coded cryptographic key . The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2026-5548 1 Tenda 1 Ac10 Firmware 2026-04-05 8.8 High
A vulnerability was found in Tenda AC10 16.03.10.10_multi_TDE01. Affected by this vulnerability is the function fromSysToolChangePwd of the file /bin/httpd. Performing a manipulation of the argument sys.userpass results in stack-based buffer overflow. The attack can be initiated remotely.
CVE-2026-5547 1 Tenda 1 Ac10 Firmware 2026-04-05 6.3 Medium
A vulnerability has been found in Tenda AC10 16.03.10.10_multi_TDE01. Affected is the function formAddMacfilterRule of the file /bin/httpd. Such manipulation leads to os command injection. It is possible to launch the attack remotely. Multiple endpoints might be affected.
CVE-2025-12622 1 Tenda 2 Ac10, Ac10 Firmware 2026-02-24 8.8 High
A vulnerability was determined in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function formSysRunCmd of the file /goform/SysRunCmd. This manipulation of the argument getui causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
CVE-2025-67073 1 Tenda 4 Ac10, Ac10 Firmware, Ac10v4 and 1 more 2026-01-02 9.8 Critical
A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field `serviceName`) to /goform/AdvSetMacMtuWan.
CVE-2025-67074 1 Tenda 4 Ac10, Ac10 Firmware, Ac10v4 and 1 more 2026-01-02 6.5 Medium
A Buffer overflow vulnerability in function fromAdvSetMacMtuWan of bin httpd in Tenda AC10V4.0 V16.03.10.20 allows remote attackers to cause denial of service and possibly code execution by sending a post request with a crafted payload (field `serverName`) to /goform/AdvSetMacMtuWan.
CVE-2018-14558 1 Tenda 6 Ac10, Ac10 Firmware, Ac7 and 3 more 2025-11-07 9.8 Critical
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
CVE-2025-57217 1 Tenda 2 Ac10, Ac10 Firmware 2025-09-03 5.3 Medium
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the Password parameter in the function R7WebsSecurityHandler.
CVE-2025-57218 1 Tenda 2 Ac10, Ac10 Firmware 2025-09-03 5.3 Medium
Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 was discovered to contain a stack overflow via the security_5g parameter in the function sub_46284C.
CVE-2025-57215 1 Tenda 2 Ac10, Ac10 Firmware 2025-09-03 7.5 High
Tenda AC10 v4.0 firmware v16.03.10.20 was discovered to contain a stack overflow via the function get_parentControl_list_Info.
CVE-2025-57219 1 Tenda 2 Ac10, Ac10 Firmware 2025-09-03 5.3 Medium
Incorrect access control in the endpoint /goform/ate of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 allows attackers to escalate privileges or access sensitive components via a crafted request.
CVE-2025-57220 1 Tenda 2 Ac10, Ac10 Firmware 2025-09-03 5.3 Medium
An input validation flaw in the 'ate' service of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 to escalate privileges to root via a crafted UDP packet.
CVE-2025-9309 1 Tenda 2 Ac10, Ac10 Firmware 2025-08-25 2.5 Low
A vulnerability was found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /etc_ro/shadow of the component MD5 Hash Handler. Performing manipulation results in hard-coded credentials. The attack needs to be approached locally. A high degree of complexity is needed for the attack. The exploitability is told to be difficult. The exploit has been made public and could be used.
CVE-2025-8178 1 Tenda 2 Ac10, Ac10 Firmware 2025-08-01 8.8 High
A vulnerability classified as critical has been found in Tenda AC10 16.03.10.13. Affected is an unknown function of the file /goform/RequestsProcessLaid. The manipulation of the argument device1D leads to heap-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-33365 2 Tenda, Tendacn 3 Ac10, Ac10 Firmware, Ac10 Firmware 2025-07-07 7.5 High
Buffer Overflow vulnerability in Tenda AC10 v4 US_AC10V4.0si_V16.03.10.20_cn allows a remote attacker to execute arbitrary code via the Virtual_Data_Check function in the bin/httpd component.
CVE-2025-45779 1 Tenda 2 Ac10, Ac10 Firmware 2025-06-13 9.8 Critical
Tenda AC10 V1.0re_V15.03.06.46 is vulnerable to Buffer Overflow in the formSetPPTPUserList handler via the list POST parameter.
CVE-2025-44175 1 Tenda 2 Ac10, Ac10 Firmware 2025-06-13 5.4 Medium
Tenda AC10 v4 V16.03.10.13 is vulnerable to Buffer Overflow in the GetParentControlInfo function.
CVE-2025-5629 1 Tenda 2 Ac10, Ac10 Firmware 2025-06-06 8.8 High
A vulnerability, which was classified as critical, was found in Tenda AC10 up to 15.03.06.47. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg of the component HTTP Handler. The manipulation of the argument startIp/endIp leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2023-45481 1 Tenda 2 Ac10, Ac10 Firmware 2025-06-05 9.8 Critical
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg.