| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the product to reset, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices.
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 |
| The Web server password authentication mechanism used by the products is vulnerable to a MitM and Replay attack. Successful exploitation of this vulnerability will allow unauthorized access of the product’s Web server to view and alter product configuration and diagnostics information.
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 |
| When an affected
product receives a valid CIP message from an unauthorized or unintended
source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port
44818/UDP that changes the product’s configuration and network
parameters, a DoS condition can occur. This situation could cause loss
of availability and a disruption of communication with other connected
devices.
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 |
| The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability, integrity, and confidentiality and a disruption in communications with other connected devices.
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 |
| When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the CPU to stop logic execution and enter a fault state, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices.
Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 |
| IBM Performance Tools for i 7.2, 7.3, 7.4, and 7.5 could allow a local user to gain elevated privileges due to an unqualified library call. A malicious actor could cause user-controlled code to run with administrator privilege. IBM X-Force ID: 284563. |
| An issue was discovered in Veritas Backup Exec before 22.2 HotFix 917391. Improper access controls allow for DLL Hijacking in the Windows DLL Search path. |
| Insecure permissions in cert-manager v1.14.4 allows attackers to access sensitive data and escalate privileges by obtaining the service account's token. |
| A vulnerability, which was classified as critical, was found in zzskzy Warehouse Refinement Management System 3.1. Affected is the function ProcessRequest of the file /AcceptZip.ashx. The manipulation of the argument file leads to unrestricted upload. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Mercedes-Benz head-unit NTG6 has Ethernet pins on Base Board to connect module CSB. Attacker can connect to this pins and get access to internal network. A race condition can be acquired and attacker can spoof “UserData” with desirable file path and access it though backup on USB. |
| Mercedes-Benz head-unit NTG6 has Ethernet pins on Base Board to connect module CSB. Attacker can connect to these pins and get access to internal network. As a result, by accessing a specific port an attacker can send call request to all registered services in router and achieve command injection vulnerability. |
| StreamLabs Desktop Application 1.9.0 is vulnerable to Incorrect Access Control via obs64.exe. An attacker can execute arbitrary code via a crafted .exe file. |
| Linksys E2000 Ver.1.0.06 build 1 is vulnerable to authentication bypass via the position.js file. |
| In dotCMS dashboard, the Tools and Log Files tabs under System → Maintenance Portlet, which is and always has been an Admin portlet, is accessible to anyone with that portlet and not just to CMS Admins. Users that get site admin but not a system admin, should not have access to the System Maintenance → Tools portlet. This would share database username and password under Log Files and download DB Dump and other dotCMS Content under Tools. Nothing in the System → Maintenance should be displayed for users with site admin role. Only system admins must have access to System Maintenance.
OWASP Top 10 - A01) Broken Access Control
OWASP Top 10 - A04) Insecure Design |
| A settings manipulation vulnerability in NCR Terminal Handler v1.5.1 allows attackers to execute arbitrary commands, including editing system security auditing configurations. |
| An issue in NCR Terminal Handler v.1.5.1 allows a remote attacker to escalate privileges via a crafted POST request to the grantRolesToUsers, grantRolesToGroups, and grantRolesToOrganization SOAP API component. |
| The potential exists for exposure of the product's password used to restrict unauthorized access to Rockwell PLC5/SLC5/0x/RSLogix 1785-Lx and 1747-L5x controllers. The potential exists for an unauthorized programming and configuration client to gain access to the product and allow changes to the product’s configuration or program. When applicable, upgrade product firmware to a version that includes enhanced security functionality compatible with Rockwell Automation's FactoryTalk Security services. |
| Incorrect configuration in deb package in ClickHouse before 1.1.54131 could lead to unauthorized use of the database. |
| A vulnerability classified as critical was found in Campcodes Online Recruitment Management System 1.0. Affected by this vulnerability is an unknown functionality of the file /admin/ajax.php?action=save_settings of the component About Content Page. The manipulation of the argument img leads to unrestricted upload. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. |
| Authentication Bypass Using an Alternate Path or Channel vulnerability in Yepas Digital Yepas allows Authentication Bypass.This issue affects Digital Yepas: before 1.0.1.
|