Search Results (34 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2002-2446 1 Gehealthcare 3 Millennium Mg Firmware, Millennium Myosight Firmware, Millennium Nc Firmware 2025-04-12 N/A
GE Healthcare Millennium MG, NC, and MyoSIGHT has a password of insite.genieacq for the insite account that cannot be changed without disabling product functionality for remote InSite support, which has unspecified impact and attack vectors.
CVE-2003-1603 1 Gehealthcare 1 Discovery Vh 2025-04-12 N/A
GE Healthcare Discovery VH has a default password of (1) interfile for the ftpclient user of the Interfile server or (2) "2" for the LOCAL user of the FTP server for the Codonics printer, which has unspecified impact and attack vectors.
CVE-2004-2777 1 Gehealthcare 1 Centricity Image Vault Firmware 2025-04-12 N/A
GE Healthcare Centricity Image Vault 3.x has a password of (1) gemnet for the administrator account, (2) webadmin for the webadmin administrator account of the ASACA DVD library, (3) an empty value for the gemsservice account of the Ultrasound Database, and possibly (4) gemnet2002 for the gemnet2002 account of the GEMNet license server, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
CVE-2010-5306 1 Gehealthcare 3 Optima Ct520 Firmware, Optima Ct540 Firmware, Optima Ct680 Firmware 2025-04-12 N/A
GE Healthcare Optima CT680, CT540, CT640, and CT520 has a default password of #bigguy for the root user, which has unspecified impact and attack vectors.
CVE-2010-5308 1 Gehealthcare 1 Optima Mr360 Firmware 2025-04-12 N/A
GE Healthcare Optima MR360 does not require authentication for the HIPAA emergency login procedure, which allows physically proximate users to gain access via an arbitrary username in the Emergency Login screen. NOTE: this might not qualify for inclusion in CVE if unauthenticated emergency access is part of the intended security policy of the product, can be controlled by the system administrator, and is not enabled by default.
CVE-2010-5309 1 Gehealthcare 1 Cadstream Server Firmware 2025-04-12 N/A
GE Healthcare CADStream Server has a default password of confirma for the admin user, which has unspecified impact and attack vectors.
CVE-2020-6966 1 Gehealthcare 12 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape Central Station Mai700 and 9 more 2024-11-21 10.0 Critical
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an attacker to obtain remote code execution of devices on the network.
CVE-2020-6965 1 Gehealthcare 18 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape B450 Monitor and 15 more 2024-11-21 9.9 Critical
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.
CVE-2020-6964 1 Gehealthcare 12 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape Central Station Mai700 and 9 more 2024-11-21 8.6 High
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.
CVE-2020-6963 1 Gehealthcare 12 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape Central Station Mai700 and 9 more 2024-11-21 10.0 Critical
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code.
CVE-2020-6962 1 Gehealthcare 18 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape B450 Monitor and 15 more 2024-11-21 10.0 Critical
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution.
CVE-2020-6961 1 Gehealthcare 12 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape Central Station Mai700 and 9 more 2024-11-21 10.0 Critical
In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files.
CVE-2020-25179 1 Gehealthcare 224 1.5t Brivo Mr355, 1.5t Brivo Mr355 Firmware, 3.0t Signa Hd 16 and 221 more 2024-11-21 9.8 Critical
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.
CVE-2020-25175 1 Gehealthcare 224 1.5t Brivo Mr355, 1.5t Brivo Mr355 Firmware, 3.0t Signa Hd 16 and 221 more 2024-11-21 9.8 Critical
GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.