Metrics
Affected Vendors & Products
No advisories yet.
Solution
Milesight advises all users to update their device to the latest firmware versions of PE/PC/PA found at https://www.milesight.com/support/download/firmware. https://www.milesight.com/support/download/firmware MS-Cxx63-PD: Update to 51.7.0.77-r13 MS-Cxx64-xPD: Update to 51.7.0.77-r13 MS-Cxx73-xPD: Update to 51.7.0.77-r13 MS-Cxx75-xxPD: Update to 51.7.0.77-r13 MS-Cxx83-xPD: Update to 51.7.0.77-r13 MS-Cxx74-PA: Update to 3x.8.0.3-r13 MS-C8477-HPG1: Update to 63.8.0.4-r4 MS-C8477-PC: Update to 48.8.0.4-r4 MS-C5321-FPE: Update to 62.8.0.4-r6 MS-Cxx72-xxxPE: Update to 61.8.0.5-r2 MS-Cxx62-xxxPE: Update to 61.8.0.5-r2 MS-Cxx52-xxxPE: Update to 61.8.0.5-r2 MS-Cxx66-xxxPE: Update to 61.8.0.5-r2 MS-Cxx66-xxxGPE: Update to 61.8.0.5-r2 MS-Cxx61-xxxPE: Update to 61.8.0.5-r2 MS-Cxx67-xxxPE: Update to 61.8.0.5-r2 MS-Cxx71-xxxPE: Update to 61.8.0.5-r2 MS-Cxx41-xxxPE: Update to 61.8.0.5-r2 MS-Cxx76-PE: Update to 61.8.0.5-r2 MS-Cxx65-PE: Update to 61.8.0.5-r2 MS-Cxx66-xxxG1: Update to 63.8.0.5-r4 MS-Cxx62-xxxG1: Update to 63.8.0.5-r4 MS-Cxx72-xxxG1: Update to 63.8.0.5-r4 MS-CQxx31-xxxG1: Update to CQ_63.8.0.5-r2 MS-CQxx68-xxxG1: Update to CQ_63.8.0.5-r2 MS-CQxx72-xxxG1: Update to CQ_63.8.0.5-r2 MS-Nxxxx-NxE: Update to 7x.9.0.19-r6 MS-Nxxxx-xxC: Update to 7x.9.0.19-r6 MS-Nxxxx-xxE: Update to 7x.9.0.19-r6 MS-Nxxxx-xxG: Update to 7x.9.0.19-r6 MS-Nxxxx-xxH: Update to 7x.9.0.19-r6 MS-Nxxxx-xxT: Update to 7x.9.0.19-r6 PMC8266-FPE: Update to PO_61.8.0.4-r1 PMC8266-FGPE: Update to PO_61.8.0.4-r1 PM3322-E: Update to PI_61.8.0.3-r5 TS4466-X4RIPG1: Update to T_63.8.0.4-r4 TS5366-X12RIPG1: Update to T_63.8.0.4-r4 TS8266-X4RIPG1: Update to T_63.8.0.4-r4 TS4466-X4RIVPG1: Update to T_63.8.0.4-r4 TS4466-RFIVPG1: Update to T_63.8.0.4-r4 TS8266-X4RIVPG1: Update to T_63.8.0.4-r4 TS8266-RFIVPG1: Update to T_63.8.0.4-r4 TS4466-X4RIWG1: Update to T_63.8.0.4-r4 TS8266-X4RIWG1: Update to T_63.8.0.4-r4 TS5510-GVH: Update to T_47.8.0.4-r8 TS5510-GH: Update to T_47.8.0.4-r8 TS5511-GVH: Update to T_47.8.0.4-r8 TS2966-X12TPE: Update to T_61.8.0.4-r4 TS4466-X4RPE: Update to T_61.8.0.4-r4 TS5366-X12PE: Update to T_61.8.0.4-r4 TS8266-X4PE: Update to T_61.8.0.4-r4 TS2966-X12TVPE: Update to T_61.8.0.4-r4 TS4466-X4RVPE: Update to T_61.8.0.4-r4 TS5366-X12VPE: Update to T_61.8.0.4-r4 TS8266-X4VPE: Update to T_61.8.0.4-r4 TS4441-X36RPE: Update to T_61.8.0.4-r4 TS4441-X36RE: Update to T_61.8.0.4-r4 TS4466-X4RWE: Update to T_61.8.0.4-r4 TS8266-X4WE: Update to T_61.8.0.4-r4 MS-C2964-RFLPC: Update to T_45.8.0.3-r10 MS-C2972-RFLPC: Update to T_45.8.0.3-r10 MS-C2966-RFLWPC: Update to T_45.8.0.3-r10 TS2866-X4TPC: Update to T_45.8.0.3-r10 TS2866-X4TVPC: Update to T_45.8.0.3-r10 TS2866-X4TGPC: Update to T_45.8.0.3-r10 TS2841-X36TPC: Update to T_45.8.0.3-r10 TS2841-X36TPC/W: Update to T_45.8.0.3-r10 TS2867-X5TPC: Update to T_45.8.0.3-r10 TS2961-X12TPC: Update to T_45.8.0.3-r10 TS8266-FPC/P: Update to T_45.8.0.3-r10 MS-C2966-X12RLPC: Update to T_45.8.0.3-r10 MS-C2966-X12RLVPC: Update to T_45.8.0.3-r10 MS-C5366-X12LPC: Update to T_45.8.0.3-r10 MS-C5366-X12LVPC: Update to T_45.8.0.3-r10 MS-C5361-X12LPC: Update to T_45.8.0.3-r10 MS-Cxx66-xxxxGOPC: Update to 45.8.0.2-AIoT-r5 SC211: Update to C_21.1.0.8-r5 SP111: Update to 52.8.0.4-r6 MS-Cxx66-RFIPKG1: Update to 63.8.0.5-r2-NX MS-Cxx72-RFIPKG1: Update to 63.8.0.5-r2-NX MS-Cxx66-FIPKG1: Update to 63.8.0.5-r2-NX MS-Cxx72-FIPKG1: Update to 63.8.0.5-r2-NX
Workaround
No workaround given by the vendor.
Tue, 28 Apr 2026 01:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | An out-of-bounds memory access vulnerability exists in specific firmware versions of Milesight AIOT cameras. | |
| Title | Milesight Cameras Heap-based Buffer Overflow | |
| Weaknesses | CWE-122 | |
| References |
| |
| Metrics |
cvssV3_1
|
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: icscert
Published:
Updated: 2026-04-27T23:45:52.896Z
Reserved: 2026-03-12T17:51:09.860Z
Link: CVE-2026-20766
No data.
Status : Received
Published: 2026-04-28T01:16:00.233
Modified: 2026-04-28T01:16:00.233
Link: CVE-2026-20766
No data.
OpenCVE Enrichment
No data.